| Unit of measurement | Cabrio Base V2 100 T | ||
| Speed | - | 1 | 2 |
| Minimum supply voltage | V | 220 | |
| Maximum supply voltage | V | 240 | |
| Power supply frequency | Hz | 50 | |
| Rated power | W | 6 | 8.5 |
| Unit current | A | 0.039 | 0.063 |
| Maximum airflow | m³/h | 60 | 90 |
| Sound pressure level LpA at 3 m | dB(A) | 22 | 25 |
| Weight | kg | 0.55 | |
| Ambient air temperature min | °С | 1 | |
| Ambient air temperature max | °С | 40 | |
| Ingress protection rating | - | IP44 | |
| Impeller material | - | Plastic | |
| Article | - | 8046810 | |
| Trademark | Blauberg | |||||
| Model | Cabrio Base V2 100 T | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -33.7 | B | -15.8 | E | -5.5 | F | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | 2-speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 90 | |||||
| Electric power input (W) | 8.5 | |||||
| Reference flow rate (m³/s) | 0.017 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.1 | |||||
| Control typology | Clock control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU UVU | |||||
| Sound power level (dB(A)) | 42 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 118 | 118 | 118 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 3667 | 1874 | 848 | ||||
| Name | Photo | Description |
|---|---|---|
| Blauberg CDP-2/5 |
|
Multi-speed switch |
| Blauberg CDP-2/10 |
|
Multi-speed switch |